o nut-monitor.service - Network UPS Tools - power device monitor and shutdown controller Loaded: loaded (/lib/systemd/system/nut-monitor.service; enabled; vendor preset: enabled) Active: failed (Result: protocol) since Tue 2020-12-29 16:12:07 EST; 10s ago Process: 2734 ExecStart=/sbin/upsmon (code=exited, status=0/SUCCESS) Dec 29 16:12:07 ctalab-Precision-3630-Tower systemd[1]: Starting Network UPS Tools - power device monitor and shutdown controller... Dec 29 16:12:07 ctalab-Precision-3630-Tower upsmon[2734]: upsmon disabled, please adjust the configuration to your needs Dec 29 16:12:07 ctalab-Precision-3630-Tower upsmon[2734]: Then set MODE to a suitable value in /etc/nut/nut.conf to enable it Dec 29 16:12:07 ctalab-Precision-3630-Tower systemd[1]: nut-monitor.service: Can't open PID file /var/run/nut/upsmon.pid (yet?) after start: No such file or directory Dec 29 16:12:07 ctalab-Precision-3630-Tower systemd[1]: nut-monitor.service: Failed with result 'protocol'. Dec 29 16:12:07 ctalab-Precision-3630-Tower systemd[1]: Failed to start Network UPS Tools - power device monitor and shutdown controller.
(base) ctalab@ctalab-Precision-3630-Tower:~$ sudo systemctl enable nut-server Synchronizing state of nut-server.service with [[SysV][SysV]] service script with /lib/systemd/systemd-sysv-install. Executing: /lib/systemd/systemd-sysv-install enable nut-server Broadcast message from nut@ctalab-Precision-3630-Tower (somewhere) (Tue Dec 29 Communications with UPS nevis-ctalab-ups@localhost established (base) ctalab@ctalab-Precision-3630-Tower:~$ sudo systemctl enable nut-monitor (base) ctalab@ctalab-Precision-3630-Tower:~$ sudo systemctl start nut-server (base) ctalab@ctalab-Precision-3630-Tower:~$ sudo systemctl start nut-monitor (base) ctalab@ctalab-Precision-3630-Tower:~$ sudo upsc nevis-ctalab-ups Init SSL without certificate database ambient.1.humidity.alarm.high: 60.00 ambient.1.humidity.alarm.low: 30.00 ambient.1.temperature.alarm.high: 40.00 ambient.1.temperature.alarm.low: 10.00 battery.charge: 100.00 battery.current: 0.00 battery.current.total: 0.00 battery.date: 08/24/2020 battery.runtime: 20100.00 battery.runtime.low: 120 battery.voltage: 27.20 device.mfr: APC device.model: Smart-UPS 1500 device.serial: C12034180352 device.type: ups driver.name: snmp-ups driver.parameter.mibs: apcc driver.parameter.pollinterval: 2 driver.parameter.port: nevis-ctalab-ups.nevis.columbia.edu driver.parameter.synchronous: no driver.version: 2.7.4 driver.version.data: apcc MIB 1.2 driver.version.internal: 0.97 input.frequency: 59.90 input.sensitivity: high input.transfer.high: 127 input.transfer.low: 106 input.transfer.reason: selfTest input.voltage: 120.80 input.voltage.maximum: 120.80 input.voltage.minimum: 120.10 output.current: 0.00 output.frequency: 59.90 output.voltage: 120.80 output.voltage.nominal: 120 ups.delay.shutdown: 120 ups.delay.start: 10 ups.firmware: UPS 09.3 (ID18) ups.id: ctalab ups.load: 0.00 ups.mfr: APC ups.mfr.date: 08/24/2020 ups.model: Smart-UPS 1500 ups.serial: C12034180352 ups.status: OL ups.temperature: 19.70 ups.test.date: 12/29/2020 ups.test.result: Ok
I | Attachment | History | Action | Size | Date | Who | Comment |
---|---|---|---|---|---|---|---|
![]() |
20201202_172538.jpg | r1 | manage | 3885.5 K | 2020-12-09 - 17:38 | ColinAdams |