2022-02-07
Author: Colin, Massimo
connection profiles on ctalab computer (odo)
Ethernet for internet (eno1) should be connected with Profile 1
Ethernet for media converter (enp3s0) should be connected with
TargetC
Hooking everything up to power now
Found that the 0.5 A level we set was current limiting, specifically to a spike in current at the start
We have raised the current limit to 1.0 A and now it seems to be working
With 12 V applied through adapter board to FEE (prior to connection), current holds steady at 0.64 A
Our module is module 3
working in software base: ~/software/CTA/svn/CCC/TargetIO/trunk/
./INFN_FEE_QC.py -cfg defaults.yaml -p 3
--
Colin Adams - 2022-02-07